# Adds AWS IoT device SDK for embedded C configuration
|
|
#
|
|
|
|
# Customer specific MQTT HOST
|
|
AWS_IOT_MQTT_HOST ?= ""
|
|
|
|
# Default port for MQTT/S
|
|
AWS_IOT_MQTT_PORT ?= "8883"
|
|
|
|
# Thing Name of the Shadow the device is associated with
|
|
AWS_IOT_MY_THING_NAME ?= "AWS-IoT-C-SDK"
|
|
|
|
# Root CA file name
|
|
AWS_IOT_ROOT_CA_FILENAME ?= "rootCA.crt"
|
|
|
|
# Device signed certificate file name
|
|
AWS_IOT_CERTIFICATE_FILENAME ?= "cert.pem"
|
|
|
|
# Device private key filename
|
|
AWS_IOT_PRIVATE_KEY_FILENAME ?= "privkey.pem"
|
|
|
|
# MQTT PubSub
|
|
|
|
# Any time a message is sent out through the MQTT layer. The message is copied
|
|
# into this buffer anytime a publish is done.
|
|
# This will also be used in the case of Thing Shadow
|
|
AWS_IOT_MQTT_TX_BUF_LEN ?= "512"
|
|
|
|
# Any message that comes into the device should be less than this buffer size.
|
|
# If a received message is bigger than this buffer size the message will be
|
|
# dropped
|
|
AWS_IOT_MQTT_RX_BUF_LEN ?= "512"
|
|
|
|
# Maximum number of topic filters the MQTT client can handle at any given time.
|
|
# This should be increased appropriately when using Thing Shadow
|
|
AWS_IOT_MQTT_NUM_SUBSCRIBE_HANDLERS ?= "5"
|
|
|
|
# Thing Shadow specific configs
|
|
|
|
# At any given time we will wait for this many responses.
|
|
# This will correlate to the rate at which the shadow actions are requested
|
|
MAX_ACKS_TO_COMEIN_AT_ANY_GIVEN_TIME ?= "10"
|
|
|
|
# We could perform shadow action on any thing Name and this is maximum Thing
|
|
# Names we can act on at any given time
|
|
MAX_THINGNAME_HANDLED_AT_ANY_GIVEN_TIME ?= "10"
|
|
|
|
# These are the max tokens that is expected to be in the Shadow JSON document.
|
|
# It includes the metadata that gets published
|
|
MAX_JSON_TOKEN_EXPECTED ?= "120"
|
|
|
|
# The Thing Name should not be bigger than this value. Modify this if the Thing
|
|
# Name needs to be bigger
|
|
MAX_SIZE_OF_THING_NAME ?= "20"
|
|
|
|
# Auto Reconnect specific config
|
|
|
|
# Minimum time before the First reconnect attempt is made as part of the
|
|
# exponential back-off algorithm (milliseconds)
|
|
AWS_IOT_MQTT_MIN_RECONNECT_WAIT_INTERVAL ?= "1000"
|
|
|
|
# Maximum time interval after which exponential back-off will stop attempting
|
|
# to reconnect (milliseconds)
|
|
AWS_IOT_MQTT_MAX_RECONNECT_WAIT_INTERVAL ?= "128000"
|
|
|
|
# Logging level control: error, warn, info, debug, trace.
|
|
AWS_IOT_LOGGING_LEVEL ?= "debug"
|
|
|
|
def get_log_level(d):
|
|
levels = ['error', 'warn', 'info', 'debug', 'trace']
|
|
log_flags = ""
|
|
|
|
log_level = d.getVar('AWS_IOT_LOGGING_LEVEL')
|
|
if log_level == 'none':
|
|
return ""
|
|
if log_level not in levels:
|
|
log_level = "debug"
|
|
d.setVar('AWS_IOT_LOGGING_LEVEL', log_level)
|
|
|
|
log_index = levels.index(log_level)
|
|
for i, val in enumerate(levels):
|
|
log_flags = log_flags + "-DENABLE_IOT_" + val.upper() + " "
|
|
if i == log_index:
|
|
break;
|
|
|
|
return log_flags
|
|
|
|
#######################
|
|
# AWS Greengrass Core #
|
|
#######################
|
|
|
|
#
|
|
# Verisign root CA server certificate used to authenticate the AWS IoT server.
|
|
#
|
|
# https://www.symantec.com/content/en/us/enterprise/verisign/roots/VeriSign-Class%203-Public-Primary-Certification-Authority-G5.pem
|
|
#
|
|
AWS_GGCORE_ROOT_CA ?= "aws-root-ca.pem"
|
|
|
|
# Greengrass core device certificate
|
|
AWS_GGCORE_CERTIFICATE ?= "gg-core.pem"
|
|
|
|
# Greengrass core device private key
|
|
AWS_GGCORE_PRIVATE_KEY ?= "gg-core.key"
|
|
|
|
# Greengrass core Thing ARN
|
|
AWS_GGCORE_THING_ARN ?= ""
|
|
|
|
# AWS IoT endpoint (check your account)
|
|
# CLI: aws iot describe-endpoint
|
|
AWS_GGCORE_IOT_HOST ?= ""
|